Outsulation X System Installation Details (DS837)
Exterior Wall Insulation and Finish System Utilizing Dow® Extruded Polystyrene With Moisture Drainage
Printer Friendly Set of Outsulation X System Installation Details in PDF format
Printer Friendly Set of Outsulation X System Installation Details in DWG format
Table Of Contents:
(printer
friendly detail cover sheet) |
PDF File |
Outsulation X System Cutaway | OX.0.0.01 |
AWRB Application and Fastening Pattern | OX.0.0.02 |
Opening Preparation - AquaFlash® System or ExoAir 230 Option | OX.0.0.03 |
Opening Preparation - Dymonic 100 or Backstop® Option | OX.0.0.03a |
Opening Preparation - Backstop® NT Option | OX.0.0.04 |
Opening Flashing Integration | OX.0.0.05 |
Opening Flashing Integration - Dymonic 100 or Backstop® | OX.0.0.05a |
Inside/Outside Corners | OX.0.0.06 |
Inside/Outside Corners - Dymonic 100 or Backstop® Option | OX.0.0.06a |
Outside Corner - High Impact | OX.0.0.07 |
Termination At Grade | OX.0.0.08 |
Termination At Concrete Curb | OX.0.0.09 |
Termination At ADA Compliant Sidewalk | OX.0.0.10 |
Termination At ADA Compliant Sidewalk - Tremco Option | OX.0.0.10a |
Insulation Preparation At Wall Penetrations | OX.0.0.11 |
Storefront Window Sill - Jamb | OX.0.0.12 |
Flanged Window Sill - Jamb | OX.0.0.13 |
Storefront And Flanged Window Head | OX.0.0.14 |
Head J-Track Option | OX.0.0.14a |
Termination At Wood Framed Deck | OX.0.0.15 |
Termination At Waterproof Deck | OX.0.0.16 |
Preparation At Parapet/Wall Intersection | OX.0.0.17 |
Termination At Parapet - Cap Flashing | OX.0.0.18 |
Termination At Roof Membrane | OX.0.0.19 |
Termination At Roof Membrane - ExoAir 110AT/Dymonic 100 Option | OX.0.0.19a |
Termination At Sloped Roof | OX.0.0.20 |
Vertical Wall/Suspended Soffit Transition | OX.0.0.21 |
Transition At Soffit/Fascia Intersection | OX.0.0.22 |
Fascia/Uninsulated Soffit Transition | OX.0.0.23 |
Termination At Uninsulated Soffit Vent | OX.0.0.24 |
Horizontal Joint At Floor Line Without Weeps | OX.0.0.25 |
Horizontal Joint At Floor Line With Weeps | OX.0.0.26 |
Horizontal Joint At Floor Line With Weeps - Dymonic Simple Seal | OX.0.0.26a |
Horizontal Joint - Substrate Change | OX.0.0.27 |
Horizontal Termination At Stone Veneer | OX.0.0.28 |
Horizontal Termination At Stucco | OX.0.0.29 |
Horizontal Termination At Lapped Siding | OX.0.0.30 |
Vertical EIFS Expansion Joint | OX.0.0.31 |
Through-Wall Expansion Joint | OX.0.0.32 |
Through-Wall Expansion Joint - Dymonic Simple Seal Option | OX.0.0.32a |
Vertical Expansion Joint Flush And Recessed Options | OX.0.0.33 |
Vertical Expansion Joint - Double Seal Option | OX.0.0.34 |
Vertical Termination At Stone Veneer | OX.0.0.35 |
Penetrations | OX.0.0.36 |
Sign Attachment | OX.0.0.37 |
Aesthetic Reveals | OX.0.0.38 |
EPS Shapes | OX.0.0.39 |
Dryvit makes no representation regarding conformity of its suggestions to applicable building codes, engineering criteria, specific applications or project locations. All components indicated in illustrations, as well as others that may be required for the integrity of thesystem shall be designed, detailed and engineered by representatives of the architect, owner or contractor to be in conformance with model codes, architectural and engineering requirements pertaining to specific building projects.
Dryvit makes no warranty, expressed or implied, as to the architectural design, engineering, or workmanship of projects utilizing Dryvit systems or products.
04/06/2022