Outsulation X System Installation Details (DS837)

Exterior Wall Insulation and Finish System Utilizing Dow® Extruded Polystyrene With Moisture Drainage

Printer Friendly Set of Outsulation X System Installation Details in PDF format
Printer Friendly Set of Outsulation X System Installation Details in DWG format

Table Of Contents:

 (printer friendly detail cover sheet)
 (printer friendly table of contents)

PDF File

Outsulation X System Cutaway OX.0.0.01
AWRB Application and Fastening Pattern OX.0.0.02
Opening Preparation - AquaFlash® System or ExoAir 230 Option OX.0.0.03
Opening Preparation - Dymonic 100 or Backstop® Option OX.0.0.03a
Opening Preparation - Backstop® NT Option OX.0.0.04
Opening Flashing Integration OX.0.0.05
Opening Flashing Integration - Dymonic 100 or Backstop® OX.0.0.05a
Inside/Outside Corners OX.0.0.06
Inside/Outside Corners - Dymonic 100 or Backstop® Option OX.0.0.06a
Outside Corner - High Impact OX.0.0.07
Termination At Grade OX.0.0.08
Termination At Concrete Curb OX.0.0.09
Termination At ADA Compliant Sidewalk OX.0.0.10
Termination At ADA Compliant Sidewalk - Tremco Option OX.0.0.10a
Insulation Preparation At Wall Penetrations OX.0.0.11
Storefront Window Sill - Jamb OX.0.0.12
Flanged Window Sill - Jamb OX.0.0.13
Storefront And Flanged Window Head OX.0.0.14
Head J-Track Option OX.0.0.14a
Termination At Wood Framed Deck OX.0.0.15
Termination At Waterproof Deck OX.0.0.16
Preparation At Parapet/Wall Intersection OX.0.0.17
Termination At Parapet - Cap Flashing OX.0.0.18
Termination At Roof Membrane OX.0.0.19
Termination At Roof Membrane - ExoAir 110AT/Dymonic 100 Option OX.0.0.19a
Termination At Sloped Roof OX.0.0.20
Vertical Wall/Suspended Soffit Transition OX.0.0.21
Transition At Soffit/Fascia Intersection OX.0.0.22
Fascia/Uninsulated Soffit Transition OX.0.0.23
Termination At Uninsulated Soffit Vent OX.0.0.24
Horizontal Joint At Floor Line Without Weeps OX.0.0.25
Horizontal Joint At Floor Line With Weeps OX.0.0.26
Horizontal Joint At Floor Line With Weeps - Dymonic Simple Seal OX.0.0.26a
Horizontal Joint - Substrate Change OX.0.0.27
Horizontal Termination At Stone Veneer OX.0.0.28
Horizontal Termination At Stucco OX.0.0.29
Horizontal Termination At Lapped Siding OX.0.0.30
Vertical EIFS Expansion Joint OX.0.0.31
Through-Wall Expansion Joint OX.0.0.32
Through-Wall Expansion Joint - Dymonic Simple Seal Option OX.0.0.32a
Vertical Expansion Joint Flush And Recessed Options OX.0.0.33
Vertical Expansion Joint - Double Seal Option OX.0.0.34
Vertical Termination At Stone Veneer OX.0.0.35
Penetrations OX.0.0.36
Sign Attachment OX.0.0.37
Aesthetic Reveals OX.0.0.38
EPS Shapes OX.0.0.39

Dryvit makes no representation regarding conformity of its suggestions to applicable building codes, engineering criteria, specific applications or project locations. All components indicated in illustrations, as well as others that may be required for the integrity of thesystem shall be designed, detailed and engineered by representatives of the architect, owner or contractor to be in conformance with model codes, architectural and engineering requirements pertaining to specific building projects.

Dryvit makes no warranty, expressed or implied, as to the architectural design, engineering, or workmanship of projects utilizing Dryvit systems or products.

back to top


04/06/2022