Outsulation® RMD System™ Details (DS106)
An Exterior Wall Insulation and Finish System With
Moisture Drainage
Printer Friendly Set of
Outsulation RMD Details
in PDF format (3,161 KB)
Printer Friendly Set of
Outsulation RMD Details
in DWG format (2,725 KB)
Table Of Contents:
(printer
friendly detail cover sheet ) |
PDF File |
System 1 Cutaway | ORMD 0.0.01 |
System 1 Cutaway with Starter Board | ORMD 0.0.01a |
System 2 Cutaway | ORMD 0.0.02 |
System 2 Cutaway with Starter Board | ORMD 0.0.02a |
System 3 Cutaway | ORMD 0.0.03 |
System 4 Cutaway | ORMD 0.0.04 |
System 4 Cutaway with Starter Board | ORMD 0.0.04a |
System 5 Cutaway | ORMD 0.0.05 |
System 5 Cutaway with Starter Board | ORMD 0.0.05a |
Fastening Pattern for System 1-3 | ORMD 0.0.06 |
Opening Preparation - Sheet Type Water Resistive Barrier | ORMD 0.0.07 |
Opening Preparation - System 4 Aquaflash System Option | ORMD 0.0.08 |
Opening Preparation - System 4 Backstop NTX or Tremco ExoAir 230 Option | ORMD 0.0.09 |
Inside/Outside Corners | ORMD 0.0.10 |
Outside Corner - High Impact | ORMD 0.0.11 |
Grade Termination | ORMD 0.0.12 |
Termination at Concrete Curb | ORMD 0.0.13 |
EPS Preparation at Wall Penetrations | ORMD 0.0.14 |
Window Elevation | ORMD 0.0.15 |
Flanged and Storefront Window/Door Head | ORMD 0.0.16 |
Window/Door Head with J-Track Option | ORMD 0.0.17 |
Door Head with Brick Mold | ORMD 0.0.18 |
Self Flashing Window Sill - Jamb | ORMD 0.0.19 |
Storefront Window Sill - Jamb | ORMD 0.0.20 |
Termination at Wood Framed Deck | ORMD 0.0.21 |
Termination at Parapet - Cap Flashing | ORMD 0.0.22 |
Termination at Parapet - Solid Substrate | ORMD 0.0.23 |
Termination at Sloped Roof | ORMD 0.0.24 |
Termination at Roof Stop Flashing | ORMD 0.0.25 |
Chimney Enclosure | ORMD 0.0.26 |
Soffit Termination | ORMD 0.0.27 |
Soffit Termination with Frieze Board | ORMD 0.0.28 |
Vertical Wall/Suspended Soffit Transition | ORMD 0.0.29 |
Transition at Soffit/Fascia Intersection | ORMD 0.0.30 |
Fascia/Uninsulated Soffit Transition | ORMD 0.0.31 |
Termination at Uninsulated Soffit Vent | ORMD 0.0.32 |
Gable End | ORMD 0.0.33 |
Gable End with Wood Trim | ORMD 0.0.34 |
Horizontal Joint at Floor Line | ORMD 0.0.35 |
Concealed Floor Line Expansion Joint | ORMD 0.0.36 |
Vertical Expansion Joint-EIFS | ORMD 0.0.37 |
Horizontal Termination at Stone Veneer | ORMD 0.0.38 |
Vertical Termination at Stone Veneer | ORMD 0.0.39 |
Penetrations | ORMD 0.0.40 |
Shutter & Downspout Attachment | ORMD 0.0.41 |
Aesthetic Reveals | ORMD 0.0.42 |
EPS Shapes | ORMD 0.0.43 |
Sealant Configuration Options | ORMD 0.0.44 |
Dryvit makes no representation regarding conformity of its suggestions to model building codes, engineering criteria, specific applications or project locations. All components indicated in illustrations, as well as others that may be required for the integrity of the system shall be designed, detailed and engineered by representatives of the architect, owner or contractor to be in conformance with model codes, architectural and engineering requirements pertaining to specific building projects.
Dryvit makes no warranty, expressed or implied, as to the architectural design, engineering or workmanship of projects utilizing Dryvit systems or products.
The liabilities shall be as stated in the Outsulation RMD limited warranty. Contact Dryvit for a full and complete copy of the Outsulation RMD warranty.
08/23/2012