Outsulation Mineral Wool System Installation Details(DS983)

An Exterior Insulation and Finish System with Moisture Drainage that Incorporates an Air/Water-Resistive Barrier, Mineral Wool Continuous Insulation

Set of Outsulation Mineral Wool System Details (PDF) PDF File
Set of Outsulation Mineral Wool System Details (DWG) DWG File
Detail Cover Sheet PDF File
Detail Table of Contents PDF File

Table of Contents

Detail Name PDF File
Outsulation Mineral Wool System Cutaway OMW 01
AWRB Application OMW 02
Opening Preparation - Aquaflash System or ExoAir 230 with Mesh Option OMW 03
Opening Preparation - Backstop Flash and Fill or Dymonic 100 Option OMW 03a
Opening Preparation - Backstop NTX or ExoAir 230 with Mesh Option OMW 04
Opening Flashing Integration OMW 05
Opening Flashing Integration - Backstop Flash and Fill or Dymonic 100 Option OMW 05a
Mechanical Fastenings - 6 Pattern Option and Load Table OMW 06
Mechanical Fastenings - 9 Pattern Option OMW 06a
Fastener Options OMW 07
Starter Board OMW 08
Inside/Outside Corners OMW 09
Inside/Outside Corners - Backstop Flash and Fill or Dymonic 100 Option OMW 09a
Outside Corner - Corner Bead Options OMW 10
Outside Corner - High Impact OMW 10a
Termination at Grade OMW 11
Termination at Concrete Curb OMW 12
Termination at ADA Compliant Sidewalk OMW 13
Termination at ADA Compliant Sidewalk - Tremco Option OMW 13a
Termination at Waterproof Deck OMW 14
Termination at Wood Framed Deck OMW 15
Insulation Preparation at Wall Penetrations OMW 16
Storefront Window Sill - Jamb OMW 17
Storefront and Flanged Window Head OMW 18
Preparation at Parapet/Wall Intersection OMW 19
Termination at Parapet - Cap Flashing OMW 20
Termination at Roof Membrane OMW 21
Termination at Roof Membrane - ExoAir 110AT/Dymonic 100 Option OMW 21a
Termination at Sloped Roof OMW 22
Vertical Wall/Suspended Soffit Transition OMW 23
Transition at Soffit/Fascia Intersection OMW 24
Fascia/Uninsulated Soffit Transition OMW 25
Termination at Uninsulated Soffit Vent OMW 26
Horizontal Joint at Floor Line without Weeps OMW 27
Horizontal Joint at Floor Line with Weeps OMW 28
Horizontal Joint at Floor Line with Weeps - ExoAir 110AT Option OMW 28a
Horizontal Joint - Substrate Change OMW 29
Horizontal Termination at Adjacent This Profile Cladding OMW 30
Vertical EIFS Expansion Joint OMW 31
Through-Wall Expansion Joint OMW 32
Through-Wall Expansion Joint - Dymonic 100 Option OMW 32a
Vertical Expansion Joint - Flush and Recessed Options OMW 33
Vertical Expansion Joint - Double Seal Option OMW 34
Vertical Termination at Adjacent Cladding OMW 35
Penetrations OMW 36
Sign Attachment OMW 37
Aesthetic Reveals OMW 38
Field-Fabricated Mineral Wool Shapes OMW 39

The architecture, engineering, and design of the project using the Tremco and Dryvit products from Tremco CPG Inc. are the responsibility of the project's design professional. All products and systems must comply with local building codes and standards. This detail is for general information and guidance only and Tremco CPG specifically disclaims any liability for the use of this detail. The project design professional determines, in its sole discretion, whether this detail or a functionally equivalent detail is best suited for the project. This detail is subject to change without notice. Contact Tremco or Dryvit Technical Services representatives to ensure you have the most recent version.

Dryvit Technical Support: (800) 556-7752 | engineering@dryvit.com